Definition of the Location of Variable Frequency Drive оn the Pipeline Technological Plot

Vitaliy A. Shabanov, Olga V. Bondarenko, Zukhra Kh. Рavlova

Аннотация


Background
Location of the variable frequency drive of the pumps on the oil pumping station is the relevant problem of their development and adoption.
Aims and Objectives
To define location of the variable frequency drive of the pumps on the oil pumping station accounting afflux and head of the specified number of operating pumps.
Methods
The problem of the location definition of the variable frequency drive of the pumps on the oil pumping stations was solved accounting the optimal pump rotary speed and the limits for its regulation.
Results
There are established the equations of the required rotary speed of the regulating pumps.
This equations allow to find out the rotary speed of one or more pumps accounting the required oil pipeline capacity and known operating regimes of the other pumps.
The algorithm of the location definition for the variable frequency drive of the pumps on the oil pumping station along the oil pipeline is considered.

Ключевые слова


main pipeline;technological plot;oil pumping station;variable frequency drive;pump;

Полный текст:

HTM (English)

Литература


Gumerov A.G. et all. Operation of Oil Pumping Station Equipment / A.G. Gumerov, R.S. Gumerov, A.M. Akberdin. Moscow: OOO «Nedra-Biznestsentr», 2001. 475 p.

Sokol Ye.I., Baru A.Yu., Lukpanov Sh.K. Experience of Development and Introduction of Frequency Converter for Adjustable Electric Drive of the Main Oil Pipeline Pump Units // Electrical Engineering. 2004. No. 7. P. 52-57.

Zaytsev L.A., Yasinskiy G.S. Control of Main Oil Pipeline Modes of Operation. Moscow: Nedra, 1980. 187 p.

Korshak A.A., Nechvaly A.M. Pipeline Transport of Oil and Products: Manual for Universities. Ufa: OOO «DizaynPoligrafServis», 2001. 571 p.

Shabanov V.A., Kabargina O.V. Stating the Ranges of Adjusting Rotational Speed of Main Pump Units // Electrical Complexes and Systems. Inter-University Scientific Collected Articles. Ufa: UGATU, 2009. P. 145-150.

Shabanov V.A., Kabargina O.V. Influence of Pipeline's Mode of Operation on the Range of Frequency Control of the Main Pump Electric Drive // Problems of the Russian Building Complex. Mater. XIV Int. Scient.-Tech. Conf. within the Frames of the XIV Specialized Exhibition «Building. Public Utilities. Power Saving - 2010». Ufa: UGNTU, 2010. T. 2. P. 57-58.

Shabanov V.A., Kabargina O.V. Stating the Lower Limit of the Range of Frequency Control of the Main Pump Electric Drive // Electronic Scientific Journal «Oil and Gas Business». 2010. URL: http://www.ogbus.ru/authors/Shabanov/Shabanov_3.pdf. 8 p.

Shabanov V.A., Kabargina O.V. About Frequency Control of High-Voltage Motors of Oil Pumping Stations // Electric Drive, Electric Technologies and Equipment of Enterprises. Symp. III All-Russ. Scient.-Tech. Conf. (with International Participants. Ufa: ID «Churagul», 2011. P. 14-21.

Tumanskiy A.P. Optimization of the Modes of Pumping through Main Pipelines with Pumping Stations Equipped with Frequency-Controlled Drives // Transport and Storage of Oil Products. 2005. No. 8. P. 11-14.

Nechvaly A.M. Basic Problems during Design and Operation of Main Oil Pipelines: Manual. Ufa: Izd-vo UGNTU, 2005. 81 p.




DOI: http://dx.doi.org/10.17122/ntj-oil-2012-3-93-95